PROFIBUS Coupler / PROFIBUS Repeater

07-7311-9.WP/...0

Funktsioonid

  • Time flow refresh signal
  • PROFIBUS coupler/PROFIBUS repeater also for hazardous areas of Zone 1.
  • Galvanically isolated bus segments for PROFIBUS-DP and PROFIBUS-IS.
  • Availability of couplers for PROFIBUS-DP as well as for PROFIBUS-IS (intrinsically safe).

Sertifikaadid

German English PTB 97 ATEX 1068 U
German English IBExU05ATEX1074 (Module)
English IECEx PTB 11.0083U
English IECEx IBE 12.0021
English CSA 2484303
Russian GOST R POCC DE.ME92.B02630
Kazakh GOST-K-KZ4710193.01.01.00136
Byelorussian GOSPROMNADZOR 11-02-0015-2012
Portuguese IEE 12.0200U

Ex kaitse liik

Ex i:
Ex II 2 G / I M2
Ex d e [ib] IIC Gb
Ex d e [ib] I Mb
Class I Zone 1 IIC
A/Ex d e [ib] IIC Gb
Ex e:
Ex II 2 G / I M2
Ex d e IIC Gb
Ex d e I Mb
Class I Zone 1 IIC
A/Ex d e IIC Gb

Ümbritseva keskkonna temperatuur

Directive 2004/108/EC
Directive 94/9/EC

Kirjeldus

The PROFIBUS couplers and PROFIBUS repeaters have been particularly dimensioned for the industrial requirements of hazardous areas of zone 1.

PROFIBUS couplers and PROFIBUS repeaters are used for the separation or generation of new segments, converting the RS485 typical line structure into an open and flexible tree structure. Downstream stations can be coupled to and decoupled from the superior bus system in a nonreactive and break/short-circuit tolerant manner, even during running bus operation.

The devices facilitate a duplication of the signal to realize a redundant connection to a master.

The devices are available as PROFIBUS-DP and as PROFIBUS-IS (intrinsically safe).

Module tasks:
  • Separation of bus segments or generation of new segments
  • Creation of complex networks in line, star and tree structures
  • PROFIBUS-conforming regeneration of the bus signals in amplitude and time
  • Increase of station number
  • Segment cascading for range increase
  • Provision of intrinsically safe bus segments for Ex i version in acc. with RS485 IS.

Tehnilised andmed (väljavõte)

(Täpsema info jaoks klikka siia)
Protection classModule: IP 66
Terminals: IP 20
Terminals with cover: IP 30
StructureFlameproof, clip-on enclosure for TH 35 rail
Dimensions(height x width x depth)
94 mm x 30 mm x 91 mm
94 mm x 75 mm x 91 mm
MaterialHigh-quality thermoplastic
Storage temperature-20 ?C to +70 ?C
WeightModule width 30 mm: 180 g
Module width 75 mm: 250 g
DisplayLED green: Operational readiness
LED green/yellow: Bus activity
VoltageSupply voltage: DC 24 V +/- 10 %
Currentapprox. 140 mA
Transmission rateEx e:
Kbit/s- 4, 8/9, 6/19, 2/45, 45/93, 75/187, 5/250/375/500/750
Mbit/s- 1.0/1.5/2.0/3.0/6.0/12.0
Ex i:
Kbit/s- 4, 8/9, 6/19, 2/45, 45/93, 75/187, 5/250/375/500/750
Mbit/s- 1.0/1.5
Bus interfaceRS485 interface
PROFIBUS-DP, PROFIBUS-IS
EN 61158-2; EN 61784-1
Connection2.5 mm?, fine stranded

Dokumentatsioon

Data Sheet - PROFIBUS Coupler / PROFIBUS Repeater German English French Russian 