Position switch thermoplastic
07-2931-1
Features
- Dimensions and mounting dimensions according to DIN EN 50041
- Electronic switching inserts with individually adjustable switching points
- Analog switching inserts can transmit through current or voltage paths
- All mechanical N/C contacts as positive opening operation contacts
- Actuating elements can be turned by 4 x 90
Certificates
GOST R POCC DE.ME92.B02510
GOST R POCC DE.ME92.B02320
PPC 00-044211
GOST-K-KZ4710193.01.01.00120
Ex protection type
II 2D Ex tD A21 IP 66 T 80 °C
CE 0044
Ambient temperature
Description
Position switches are used wherever movable parts on machinery and systems have to be positioned, controlled and monitored.They control and facilitate signalling in switching gear or function as switches in regulating and control devices.
The flameproof encapsulated BARTEC position switches can be used in hazardous (potentially explosive) areas in Zones 1 and 2 in accordance with the certified explosion subgroups IIA, IIB and IIC and the temperature class T6 and in Zones 21 and 22 according to the certified maximum surface temperature.
Technical data (extract)
(Click here for more information)Protection class | IP 66 (IEC 60529) |
Dimensions | see data sheet |
Material | Enclosure /plunger material: Injection moulding made of thermoplastic |
Mechanical life | max. 106 switching cycles depending on plunger operating angle/speed |
Weight | approx. 160 g |
Voltage | Mechanical switching unit: Rated insulation voltage: 400 V Rated operating voltage /current: AC 15, 4 A, 400 V AC 15, 6 A, 24 V and 240 V DC 13, 3 A, 24 V DC 13, 0.8 A, 110 V DC 13, 0.3 A, 220 V Rated impulse strength: 4 kV AC Electronic switching unit: Rated voltage: up to 30 V DC Rated operating voltage/current: DC 12 V, 0.015 A DC 24 V, 0.018 A DC 30 V, 0.019 A |
Frequency | Switching frequency: up to 6000 / h depending on the type |
Electrical life | depending on load |