Pressurized Solutions for Zone 1, 2 or 22

Certificates

German English BVS 11 ATEX E 144
German English BVS 11 ATEX E 145
English IECEx BVS 13.0049
English IECEx BVS 11.0070
English CSA 2654546
Chinese NEPSI GYJ13.1199
English Chinese CNEx13.1354X
Russian GOST R POCC DE.ME92.B02732
Kazakh GOST-K-KZ4710193.01.01.00142

Ex protection type

APC ATEX:
Ex II 2G Ex px IIC T3 - T6 Gb
Ex II 2G Ex px ib IIC T3 - T6 Gb
APC IECEx:
Ex px IIC T3 - T6 Gb
Ex px ib IIC T3 - T6 Gb
SPC ATEX:
Ex II 3G Ex pz IIC T3 - T6 Gc
Ex II 3G Ex pz ib IIC T3 - T6 Gc
SPC IECEx:
Ex pz IIC T3 - T6 Gc
Ex pz ib IIC T3 - T6 Gc

Ambient temperature

Directive 2004/108/EC
Directive 94/9/EC

Description

The demand of complex automation functions for processes in the field of chemistry, pharmacy, oil and gas calls for flexible, safe and maintenancefriendly solutions for measuring, controlling, regulating and visualization tasks, particularly in potentially explosive areas. Complete control systems and switchgear, motors, actuators and pumps, open-plan displays, industrial monitors incl. keyboards and printers must be made ready for applications in hazardous areas. For many applications the Ex p pressurized cabinet is one of the most flexible Ex solutions. Thanks to this type of protection, non-explosion proof devices can be operated in potentially explosive areas of zone 1, 2 and 22. The underlying idea is to prevent an explosive atmosphere from entering a sealed protective enclosure by generating a permanent overpressure against the surrounding atmosphere. With the pressurized cabinet, BARTEC offers a completely new Ex solution for the control and automation of devices, machines and systems in zone 1, 2 and 22. Depending on the application, non-explosionproof control units and switchgear as well as complete automation systems are mounted into the pressurized cabinet. On the basis of the modular APEX 2003 overpressure control, which has been certified in accordance with ATEX, modern, operationable Ex solutions are realized - including the required certification in accordance with 94/9/EC.

The stirring gas overpressure is realized by a compensation of the leakage losses or by permanent flushing. The pressurized cabinet has been designed for an ambient temperature between -20 ?C and +60 ?C in the temperature classes T3 to T5. For temperature class T6, an ambient temperature between -20 ?C and +40 ?C is permissible.
The maintenance and availability of the explosionproof devices and system has top priority. Within the course of many years, the BARTEC experts have gathered substantial experience with explosion protection applications as well as the conception of complete system solutions for automation. On the basis of this know-how, safe and economically efficient solutions ranging from engineering over production and procurement via commissioning and approval have been developed. Depending on the application, Ex p solutions are realized with sheet-steel or stainless steel, with air-conditioning, different lacquer coats, seawater-resistant and tropic-proof. BARTEC solutions also comprise commissioning and function checks. For integration into the already existing explosion protection document, a detailed operating manual is supplied. In addition to this, introduction and training measures for qualified staff members may be implemented upon request.

Customized Solutions

BARTEC offers customized, pressurized solutions for:
  • Devices
  • Printers
  • Operator terminals
  • Control units
  • Frequency converters
  • Monitors
  • Motors

Air-conditioning

Optionally available from BARTEC various solutions to the climate of Ex-p systems:
  • Operating heating
  • Standstill heating
  • Air cooler
  • Air-conditionier
  • Water-air cooler

Accessories

  • Stirring gas filter systems
  • Power amplifier up to 30 kW
  • Interposing relays for data performances
  • Bypass key switches

Technical data (extract)

(Click here for more information)
Protection classIP 55/IP 65
DimensionsEnclosure volume: max. 6.336 dm?
MaterialStainless steel, Coated sheet-steel
Plastic (certified separately)
PressureOverpressure range: 0 to 25 mbar
Purging gas primary pressure: 1 to 25 bar
Operating pressure: 2 to 4 mbar
Cleaning pressure: 1 to 20 mbar
Purging timeAPC: 0 to 99 minutes
SPC: 0 to 60 minutes
Switch-off delay: 5 seconds
Voltagemax. AC 690 V
Powerdepending on the application

Documentation

Data Sheet - Pressurized Solutions for Zone 1, 2 or 22 German English French Russian Spanish Portuguese Italian 
Declaration of Conformity 01-3703-7C0001 German English French 
Declaration of Conformity A1-3703-7C0001 German English French 
Customer requirements - Ex p equipment German English French Russian Spanish Portuguese Italian 
Operating Instructions - APC-APEX/SPC-SILAS Pressurized Cabinet, Type .7-37.3-..../.... German English French Russian Spanish Portuguese Italian