Local control stations for Zone 1 and Zone 21

07-3...-

Features

  • The right size enclosure
  • Optimum functionality thanks to the great variety of components
  • Customised planning and implementation
  • Certified to many standards

Certificates

German English IBExU12ATEX1099
English IECEx IBE 12.0031

Ex protection type

Zone 1:
Ex II 2 G Ex d e ma/mb op is q ia/ib [ib]
   IIA, IIB, IIC, T6, T5, T4, T3 Gb
Ex II 2(1) G Ex d e ma/mb op is q ia/ib [ia Ga]
   IIA, IIB, IIC, T6, T5, T4, T3 Gb
Zone 21:
Ex II 2D Ex tb [ib] IIIA, IIIB, IIIC
   T80 °C, T100 °C, T130 °C Db
Ex II 2(1) D Ex tb [ia Da] IIIA, IIIB, IIIC
   T80 °C, T100 °C, T130 °C Db

Ambient temperature

(special design on request)
-20 °C to +40 °C
-55 °C max. +80 °C
(depending on fixtures)

Description

BARTEC produces local control stations for use in areas with flammable gases and dusts. Depending on the application area, the control stations are designed
with the type of protection ?Increased safety? or ?Protection by enclosure?.

The explosion-protected local control stations are available in aluminium, polyester or stainless steel. When selecting the version, you can choose between a cabinet with door and an enclosure with screw cover. Control, signalling and display devices and remote I/O systems are installed according to customer specifications. The installation of industrial standard equipment in controls for Zone 21, type of protection tb ?Protection by enclosure? is possible.

The control elements can also be mounted on a mounting rail or in the front wall. Free installationa reas can be designated for the subsequent installation of BARTEC control and signalling devices, which are then sealed using blanking plugs. All explosion-protected local control stations are supplied prewired on terminals.

Fields of application

Chemical and petrochemical industry, process and plant engineering, pharmaceutical and food industry, OFF SHORE areas.

Technical data (extract)

(Click here for more information)
Protection classEN 60529/IEC 60529: IP max. IP 66
(higher degree of protection on request)
Materialsee data sheet
Voltageup to 1000 V
Currentmax. 160 A depending on devices fitted

Documentation

Data Sheet - Local control stations for Zone 1 and Zone 21 German English French Russian Spanish Portuguese Italian 
Declaration of Conformity 01-3000-7C0001 German English French 
Customer requirements - Local control station German English French Russian 
Operating Instructions Measuring, Control and Switchgear combination Type 07-3...-?./?. German English French Russian Spanish Portuguese Italian Serbian Romanian