Potentiometer for local control stations

07-3373-1D.0

Certificates

German English PTB 05 ATEX 1064 U
English IECEx PTB 10.0017U
English DNV E-11912
Korean KTL 12-KB4BO-0227U
English Portuguese UL-BR 14.0133U

Ex protection type

Ex II 2G Ex de IIC
Ex I M2 Ex de I

Ambient temperature

-55 °C up to +60 °C

Technical data (extract)

(Click here for more information)
Protection classDetermined by actuating element and control station enclosure,
Terminals: IP 20 (IEC 60529)
MaterialThermoplastic
Contact materialcarbon film on ceramics
Mechanical life> 25000 sinusoidal cycles
Storage temperature-55 ?C to +70 ?C
Weightapprox. 88 g
Voltagemax. AC/DC 320 V
Powermax. 1 W
Resistance1 kΩ to 10 kΩ
ConnectionDouble terminals 2 x 2.5 mm?, fine stranded

Documentation

Data Sheet - Potentiometer for local control stations German English French Russian Spanish 
Declaration of Conformity 01-3370-7C0001 German English French 
Operating Instructions - Potentiometer with terminals for front installation German English French Russian Spanish Portuguese Italian