Measuring transducer for Pt 100
07-7311-93T4/.350
Features
- For Pt100
- Analog output 4 to 20 mA
- Fault detector
- Ex ia, ib
- Two-, three-wire senors
- EMV according to
DIN EN 61000-6-3: 2007;
DIN EN 61000-6-4: 2007;
DIN EN 61000-6-1: 2007;
DIN EN 61000-6-2: 2006
Certificates
TUEV 97 ATEX 1204 X
IECEx PTB 11.0083U
IECEx TUN 11.0030X
CSA 2484303
GOST R POCC DE.ME92.B02630
GOST-K-KZ4710193.01.01.00136
GOSPROMNADZOR 11-02-0015-2012
IEE 12.0200U
Ex protection type
Ex d e [ia Ga] IIC/IIB Gb
Ex d e [ia Ma] I Mb
Class I Zone 1 IIC
A/Ex d e [ia] IIC Gb
Ambient temperature
Directive 94/9/EC
Description
The MODEX series includes a temperature measuring transducer mounted on-site in the same way as a modular terminal. The module transforms the signal received from the Pt100 temperature sensor into a proportional, load-independent 4 to 20 mA output signal.The sensor circuit is intrinsically safe according to Ex protection type Ex ia. An output current exceeding the 4 to 20 mA range signals a senor fault (open/short circuit). The Pt100 temperature sensor can be operate in 2- or 3-wire circuits within zone 0 or 1.
Technical data (extract)
(Click here for more information)Protection class | Module: IP 66/IEC 60529 Terminals: IP 20/IEC 60529 |
Material | High-quality thermoplastic |
Installation | TH 35 x 15 (7.5) EN 60715 |
Storage temperature | -40 ?C to +60 ?C |
Weight | 0.250 kg |
Temperature range | -50 ?C to +400 ?C (see data sheet) |
Voltage | DC 24 V + 10%, - 15% |
Output current | Load independent current: 4 to 20 mA |
Power | 0.6 W |
Connection | Terminals 2.5 mm?, fine stranded |