Freezing Point Process Analyzer FRP-4

FRP-4

Funktsioonid

  • ASTM compliance
  • Cloud Point detection possible
  • Customized solutions
  • Network and Fieldbus communication
  • Cloud Point also determinable
  • Rugged design of measuring cell
  • Optimized assembly

Sertifikaadid

German English TUEV 04 ATEX 2505
English CSA 1524800

Ex kaitse liik

Ex II 2G Ex (IIB; IIB+H2) T4
Optional available classification:
Class I, Div. 2, Groups B, C and D
Class I, Zone 1, Groups IIB or IIB+H2
Protection type depending on application

Ümbritseva keskkonna temperatuur

ASTM D 2386, ASTM D 1015
DIN ISO 3013
IP 16

Kirjeldus

The Freezing Point Prozess-Analyzer (FRP-4) is intended for use in the petrochemical industry. It serves to determine automatically the Freezing Point (FP) of liquid and transparent petrochemical products. Up to two product streams and a validation stream can be connected to the online analyzer. It is intended to monitor the quality of production in the process and also the compliance with mandatory specifications for aviation gasoline. For gasoils and diesel oils with Cloud Points (CP) at very deep temperatures you can use the FRP-4 to detect the CP.

For detection of the FP a sample is cooled down continuously under exactly defined conditions. As soon as the temperature of the sample has gone below a limit, small crystals appear. They disperse in the whole sample and make it cloudy. The temperature at a certain degree of cloudiness is called CP. By stopping the cooling process the crystals are melting. The sample becomes clear and transparent again. The temperature at which all crystals have melted is called FP.

For the use of liquid hydrocarbons it is important to know their properties and characteristics at low temperatures as the fluidity of these substances greatly influences their pumping or filtering behavior. The FP is a measuring value required to control and adjust the production process and it is a necessary specification for obtaining permission to sell the product.

Tehnilised andmed (väljavõte)

(Täpsema info jaoks klikka siia)
Protection classIP 54
Dimensions(W x H x D) approx. 1140 x 1900 x 710 mm
Weightapprox. 380 kg
Pipe fittingsSwagelok? 6 mm/12 mm (other fittings on request)
Measurement rangeLimit of range: -70 ?C (-94 ?F); optional -80 ?C (-112 ?F)
the lowest detectable freezing point temperature depends on the actual cloud point temperature which must be above the mentioned limit
DisplayTFT display with touch function (800 x 600 pixels)
Keyboardvirtual keyboard, controlled via TFT display
Operating systemWindows XP?
VoltageAC 230 V ? 10 %, 1 phase; 50 Hz (other rating on request)
AC 400 V / 50 Hz; 3 phases (for chiller)
Powermax. approx. 600 W
max. approx. 1100 W (for chiller)

Dokumentatsioon

Data Sheet - Freezing Point Process Analyzer FRP-4 German English