Remote I/O Module ANTARES 8DO-SCL

17-6143-1010/0000

Features

  • 8 channels digital out Ex ia IIC
  • Single Channel Current Limitation
  • Integrated bus rail
  • Installation in ATEX Zone 1/2
    or Zone 21/22
  • Hot-Swap
  • Galvanic isolation between the inputs and the system
  • Line break/short circuit monitoring
  • Plug-in and codable spring clamps
  • 2 LED displays per channel

Certificates

German English PTB 11 ATEX 2014
English IECEx PTB 11.0054
English DNV A-13339
Russian GOST R POCC DE.ME92.B02833
Russian RTN PPC 00-049813
Korean KTL 13-KB4BO-0306
Korean KTL 13-KB4BO-0307
English Portuguese UL BR 13.0270

Ex protection type

ATEX:
Ex II 2 (1)G Ex ib [ia IIC/IIB Ga] IIC T4 Gb
Ex II (1)D [Ex ia Da] IIIC
IECEx:
Ex ib [ia IIC/IIB Ga] IIC T4 Gb
[Ex ia Da] IIIC

Ambient temperature

EN 60079-0:2009 EN 60079-11:2007
EN 61241-0:2006 EN 61241-11:2006
EN 61000-6-2:2005 EN 61000-6-4:2007
EN 55011:2007
IEC 60079-0:2007
IEC 60079-11:2006
IEC 61241-0:2004,
modified + Corr. Nov. 2005
IEC 61241-11:2005 + Corr. Feb. 2006

Description

The Remote I/O Module ANTARES 8DO-SCL (single channel limitation) is operated and supplied with power through the Rail Control Unit (RCU) ANTARES. This module is suitable for the direct control of up to 8 intrinsically safe solenoid valves in the explosion hazardous area.

The hot swap capability allows the electronic unit to be replaced without disconnecting from voltage even in an Ex atmosphere. The internal and galvanically isolated bus connection is established by simply joining the modules to the RCU. A bus rail is not necessary. Line break/short-circuit monitoring can be programmed for each channel. The bus status messages and individual messages per channel are displayed through the LEDs. This facilitates diagnosis at the module as well. The ANTARES Designer software allows the module to be programmed and the output load to be calculated automatically. See the system description for installation instructions.

Technical data (extract)

(Click here for more information)
Protection class(EN 60529)
Enclosure: IP 30 in the ANTARES system construction
Dimensions(W x H x D) 45 mm x 110 mm x 114.5 mm
MaterialEnclosure material: PA
InstallationMounting rail TH 35-15 EN 60715 (Metal)
Storage temperature-25 ?C up to +85 ?C
Humidity5 up to 95 %, non-condensing
Vibration(EN 60068-2-6)
2 g/7 mm; 3 Hz bis 200 Hz in all 3 axes
Shock(EN 60068-2-27)
15 g, 11 ms in all 3 axes
Weightapprox. 390 g
DisplayLEDs in enclosure front:
Status ST, PWR, ERR1, ERR2
Outputs 2 LEDs per channel
1 x LED yellow Channel active
1 x LED red Channel error
InterfaceNumber of channels
8 digital outputs Ex i (short-circuit-proof)
VoltageSupply voltage: through internal bus
No-load voltage: DC 24 V
ResistanceInternal resistance: 271 Ohm
Connection- plug-in tension spring clamp 4-pole
- up to 2.5 mm?
- optional coding and numbering

Documentation

Data Sheet - Remote I/O Module ANTARES 8DO-SCL German English French Russian 
Declaration of Conformity 11-6143-7C0001 German English French