HSB system Junction box

27-5452-...11..0

Features

  • Wide temperature range
  • PLEXO connection system, cold-applied connection and shrinkable tubing technology
  • Flame-retardant
  • Shock-resistant
  • System approval

Certificates

German English KEMA 08ATEX0110 (System)
English IECEx KEM 09.0083 (System)
Russian TC RU C-SI.GB08.B.00308

Ex protection type

Ex II 2G Ex e II 200 °C (T2), T3, T4
Ex II 2D Ex tD A21 IP65 T 200 °C, T 195 °C, T 130 °C

Ambient temperature

-55°C up to + 55°C

Description

Inside the standard polyester junction box one or several heating circuits are connected to the supply AC 254 V.

One cable gland size M25 for the supply voltage is already assembled at the junction box.

The enclosure is prepared with threads for heating cable glands size M20.

Technical data (extract)

(Click here for more information)
Protection classfollowing EN 60529
Seal of cover: IP65
Cable gland: IP65
DimensionsJunction box for one heating circuit: 122 x 120 x 90 mm
Junction box for 2/3 heating circuits: 220 x 120 x 90 mm
MaterialPolyester, glass fibre reinforce
VoltageAC 254 V
CurrentProtection: Max. 32 A (dependant on the heating circuit length)
ConnectionCross section: 0,5 mm? up to 6,0 mm?

Documentation

Data Sheet - HSB system Junction box German English French Russian 