HSB system Heat shrink technology media protected
07-5803-0000/98.0
Features
- Direct insertion of a heating cable into an plastic enclosures
- Flexible connection - heating cable/cold cable
- Space-saving, favourable dimensions
- Simple project planning
Certificates
switched on up to +120 ?C
for heating cable switched off +185 ?C (cum. 1000 h)
Description
If the enclosure is connected directly, the heating cable is first stripped and then insulation tubes are shrunk over the supply lines and the twisted protective braiding and wire end sleeves are put on.The heating cable is connected directly to terminals in a junction box, IP 65 protection class.
As an alternative, the heating cable can be connected directly to a supply cable by means of a butt connector.
The heating circuit end is closed in each case with a heat shrinkable end cap.
Technical data (extract)
(Click here for more information)Voltage | AC 208 V up to AC 254 V AC 110 V up to AC 120 V |
Power | 10, 15, 25, 30, 45 and 60 W/m |