BSTW Safety Temperature Monitor, BTB/BSTB Safety Temperature Limiter16 A fail-safe
27-6A.1-..../....
Funktsioonid
- 16 A switching capacity
- Pre-set limit point for BSTB
- Suitable for use in Zone 1 + Zone 2 areas
- Temperature setting directly in Zone 1, Zone 21 and 22 areas possible
- Resettable lockout on the device
- Direct heating circuit connection via sheathed cable/cold lead
- Temperature ranges from
-20
Sertifikaadid
DNV E-10452
NEPSI GYJ11.1605
GOST R POCC DE.ME92.B02734
No. 903
GOSPROMNADZOR 11-02-0015-2012
Ex kaitse liik
II 2D tD A21 IP65 T 80 °C, T 95 °C
Ümbritseva keskkonna temperatuur
-40 °C/-55 °C on request
Max. sensor temperature: up to +345 °C
see datasheet
Kirjeldus
The 16 A Ex temperature monitor BSTW/temperature limiter BTB/BSTB are change-over controllers housed in an Ex e certified polyester enclosure.Heaters, fans, motors and other equipment are energised and de-energised by means of this thermostat when specific temperature ranges are exceeded. These devices can also be used to control the temperature in air or on various surfaces. The fail-safe temperature limiter BTB and the fail-safe temperature limiter BSTB are produced with restart lockout, resetting (reopening) is only possible at the device.
Function
Any change in temperature at the sensor bulb causes a change in the volume of fluid in the measuring system, which in turn results in a movement of the diaphragm membrane. This membrane is connected to a mechanical device that activates a microswitch. If the temperature at the sensor bulb exceeds the pre-set value, terminals 1 and 4 are opened.The BTB and BSTB devices ?lock-out? permanently if the set temperature is exceeded. After a temperature decrease of about 9 % below the set value, both BTB and BSTB can be re-set manually. If there is a rupture or break in the sensor tube (leakage), then the switch remains permanently open (fail-safe). If the temperature falls below the minimum setting, the autocontrol opens the circuit but closes again on temperature rise.
Tehnilised andmed (väljavõte)
(Täpsema info jaoks klikka siia)Protection class | IP 65 (EN 60529) |
Dimensions | Single unit 122 x 120 x 90 mm Double unit 220 x 120 x 90 mm Capillary tube: 1000 mm length OD sensor line 1.5 mm min. bend radius 5 mm sensor bulb diameter 6 mm |
Storage temperature | -50 ?C to +65 ?C |
Weight | Single unit 1.1 kg Double unit 2.0 kg |
Temperature range | BSTW: -20 ?C to +300 ?C (mechanical) BTB: 0 ?C to +300 ?C (mechanical) |
Voltage | max. AC 250 V, 50/60 Hz |
Current | Switching capacity: 16 A NC / 10 A NO |
Connection | 4 Terminals with 2.5 mm? + 1 PE Cable glands 2 x M25 |