Technical data (extract)

(Click here for more information)
MaterialCentre conductor: Copper ? 2.25 mm
Dielectric: REX (Polyethylene cross-linked) ? 7.25 mm
Outer conductor: Copper, Silver plated, braid, 95%, ? 8.15 mm
Jacket: RADOX (LSFH), RAL 9005 - bk 10.3 mm ?0.1
Print: HUBER+SUHNER GX 07272 50W (PA no.)
Weight16.1 kg/100 m
VoltageMax. operating voltage: 5 kVrms (at sea level)
Test voltage: 10 kVrms (50Hz/1 min)
ResistanceInsulation resistance >1 x 108MΩm
FrequencyMax. Operating frequency: 2 GHz

Documentation

Data Sheet - Flameproof Enclosures English 
Written Attestation of Conformity TEC-09-ATEX-TNDLD-01 English