Ex p control unit APEX 2003.SI (Dilution)
07-3711-4213/.001
Funktsioonid
- 4 voltage free contacts
- 3-line LCD display
- LED status display
- Modular design
- Fail-safe control
- Integrated valve switches for purging gas input and output
- 10 mm purging gas connection
- Connection possibility of seperate pressure sensors
Sertifikaadid
Ex kaitse liik
Ümbritseva keskkonna temperatuur
Directive 94/9/EC
Kirjeldus
The control unit APEX 2003.MV controls and monitors the purging and operating cycle of analysers with ?Containment Systems?Additional function:
Due to the internal mounting of the purging circuit, the pressurised enclosure is constantly purged with a defined quantity of purging gas.
The purging gas flow rate during purging is 4100 NI/h max. The constant purging can be set from 0 to 6.0 l/min. 4 freely programmable relay outputs are available for the separation of data lines.
Tehnilised andmed (väljavõte)
(Täpsema info jaoks klikka siia)| Protection class | IP 65 |
| Structure | Ex e protective enclosure with viewport lid |
| Material | Enclosure material: glass-fiber reinforced, polyester |
| Purging time | 0 to 99 min; 5 sec. dropout delay |
| Weight | 11 kg |
| Voltage | AC 230 V (AC 115 V) ?10% |
| Power | Pv = 15 W/230 V |
| Connection | Terminals 2.5 mm?, fine stranded |
BARTEC – THE WORLD OF SAFE.T® TECHNOLOGY