Ex p control unit APEX 2003.SI (Dilution)
07-3711-4213/.001
Features
- 4 voltage free contacts
- 3-line LCD display
- LED status display
- Modular design
- Fail-safe control
- Integrated valve switches for purging gas input and output
- 10 mm purging gas connection
- Connection possibility of seperate pressure sensors
Certificates
CSA 2654548
KTL 13-KB4BO-0634
GOST R POCC DE.ME92.B02732
GOSPROMNADZOR 11-02-0015-2012
Ex protection type
II 2(1)G Ex e d ib [ia Ga px] IIC T4 Gb
Ambient temperature
Directive 94/9/EC
Description
The control unit APEX 2003.MV controls and monitors the purging and operating cycle of analysers with ?Containment Systems?Additional function:
Due to the internal mounting of the purging circuit, the pressurised enclosure is constantly purged with a defined quantity of purging gas.
The purging gas flow rate during purging is 4100 NI/h max. The constant purging can be set from 0 to 6.0 l/min. 4 freely programmable relay outputs are available for the separation of data lines.
Technical data (extract)
(Click here for more information)Protection class | IP 65 |
Structure | Ex e protective enclosure with viewport lid |
Material | Enclosure material: glass-fiber reinforced, polyester |
Purging time | 0 to 99 min; 5 sec. dropout delay |
Weight | 11 kg |
Voltage | AC 230 V (AC 115 V) ?10% |
Power | Pv = 15 W/230 V |
Connection | Terminals 2.5 mm?, fine stranded |