Control unit APEX 2003.00I

07-3711-1210/.0..

Features

  • 4 voltage free contacts
  • 3-line LCD display
  • LED status display
  • Modular design
  • Fail-safe control

Certificates

German English DMT 99 ATEX E 082
English IECEx BVS 13.0039
Chinese NEPSI GYJ13.1200
English CSA 2654548
Korean KTL 13-KB4BO-0634
Portuguese NCC 14.02972 X
Russian GOST R POCC DE.ME92.B02732
Byelorussian GOSPROMNADZOR 11-02-0015-2012

Ex protection type

ATEX:
Ex II 2(1)G Ex e d ib [ia Ga px] IIC T4/T6 Gb
Ex II 2(1)G Ex e d [ia Ga px] IIC T6 Gb
IECEx:
Ex e d ib [ia Ga px] IIC T4/T6 Gb
Ex e d [ia Ga px] IIC T6 Gb

Ambient temperature

Directive 2004/108/EC
Directive 94/9/EC

Description

The control unit APEX 2003.00I controls and monitors the purging and operating cycle of standard enclosures and is intended for mounting inside the enclosure.

Purging gas input is via a digital valve up to NW 7.7
(74 m?/h) or a proportional valve up to NW 2 (5 m?/h).

The purge time is set at the control module via a turn switch, the setting of the pushbuttom values is via pushbutton or RS 485 interface. The control unit provides 4 freely programmable relay outputs.

Technical data (extract)

(Click here for more information)
Protection classIP 65
MaterialEnclosure material: glass-fibre reinforced polyester
Purging time0 to 99 min; 5 sec. dropout delay
Weight3.8 kg
VoltageAC 230 V (AC 115 V) ?10%
PowerPv = 8 W/230 V
ConnectionTerminals, 2.5 mm?, fine stranded

Documentation

Data Sheet - Control unit APEX 2003.00I German English French Russian Spanish Portuguese Italian 
Declaration of Conformity 01-3711-7C0001 German English French 
Customer requirements - Ex p equipment German English French Russian Spanish Portuguese Italian 
Operating instructions - Control unit APEX 2003, Type 07-3711-.2../.... German English French Russian Spanish Portuguese Italian